SN Pumps
ITEM # | HORSEPOWER | MOTOR VOLTAGE | WEIGHT (LBS) |
---|---|---|---|
SNC-HF25L
|
1/2
|
115/230
|
45
|
SNC
|
1/2
|
115/230
|
45
|
SND
|
3/4
|
115/230
|
47
|
SNE
|
1
|
115/230
|
55
|
SNF
|
1-1/2
|
115/230
|
60
|
Max. Liquid Temperature: 140°F
Max. Inlet Pressure: 50 PSI
Average Priming Time (in minutes) at 15 Feet: SNC = 2.3; SND = 1.7 SNE = 1.3; SNF = 1.1
Average Priming Time (in minutes) at 25 Feet: SNC = 6.4; SND = 4.4 SNE = 4.4; SNF = 2.6
Body: Close-grained cast iron
Nozzle: High-strength Lexan®
Venturi: Lexan
Impeller: Noryl®
Diffuser: Reinforced polypropylene
Shaft: One-piece threaded, 416 grade stainless steel
Base: Steel, 12 gauge

Projet HN Series
ITEM # | HORSEPOWER |
---|---|
HNC
|
1/2
|
HND
|
3/4
|
HNE
|
1
|
BODY CONSTRUCTION: Cast Iron
MAXIMUM CAPACITY: 28.5GPM (HNE model)
FLOW at 10′ LIFT and 40 PSI: 18.7 GPM (HND model)
MAX LIFT: 25′
MAX SHUT-OFF PRESSURE: 70 PSI (model HNC)
MAXIMUM INLET PRESSURE: 50 psi (inlet pressure + discharge not to exceed 100 psi)
PRESSURE SWITCH SETTING: 30-50 PSI
SUCTION SIZE: 1-1/4″ NPT
DISCHARGE SIZE: 1″ NPT
AMP DRAW (full load): 19.2 amps (1 HP running on 115v)
VOLTAGE: 230v / 115v AC, 60 Hz, single-phase (factory pre-set at 230v)
RECOMMENDED BREAKER: Model and Voltage Dependent
MAXIMUM LIQUID TEMPERATURE: 140°F / 60°C

SSJ Series Vertical Jet Pumps
ITEM # | HORSEPOWER |
---|---|
SSJC
|
1/2
|
SSJD
|
3/4
|
SSJE
|
1
|
BODY CONSTRUCTION: Cast Iron
MAXIMUM CAPACITY: 9.5 GPM (with 4″ double-pipe setup)
FLOW at 50′ LIFT and 40 PSI: 6.3 GPM (with 4″ double-pipe setup)
MAX LIFT: 80′
MAX SHUT-OFF PRESSURE: 102 PSI (SSJE at shallow depth-to-water)
PRESSURE SWITCH SETTING: 40 – 60 PSI
SUCTION SIZE: 1-1/4″ NPT
DISCHARGE SIZE: 1″ NPT
DRIVE SIZE: 1″ NPT
VOLTAGE: 115v / 230v, 60 Hz, 1-phase
MAXIMUM LIQUID TEMPERATURE: 140 F (60 C)

PL Series
ITEM # | HORSEPOWER |
---|---|
PLC
|
1/2
|
PLD
|
3/4
|
PLE
|
1
|
PLF
|
1-1/2
|
BODY CONSTRUCTION: Thermoplastic
MAXIMUM CAPACITY: 26.3 GPM (Model PLE with Shallow Well Setup)
FLOW at 10′ LIFT and 40 PSI: 13.8 GPM (Model PLD Shallow Well Setup)
MAX LIFT: 25′ w/ Shallow Well jet Kit / 60′ w/ Deep Well Jet Kit
MAX SHUT-OFF PRESSURE: 72 PSI (model PLC in shallow well config)
MAXIMUM TOTAL PRESSURE (Inlet + Pump Pressure): PLC: 72 PSI / PLD:62 PSI / PLE: 62 PSI / PLF: 64 PSI
PRESSURE SWITCH SETTING: 30-50 PSI
SUCTION SIZE: 1-1/4″ NPR
DRIVE SIZE: 1″ NPT (suction-over-drive)
DISCHARGE SIZE: 1″ NPT
AMP DRAW (full load): 6.1 amps on 230v / 12.2 amps on 115v
VOLTAGE: 115v/230v AC, 60 Hz, 1-phase
MAXIMUM LIQUID TEMPERATURE: 140 F (60 C)

PN Series pumps
ITEM # | HORSEPOWER |
---|---|
PNC
|
1/2
|
PND
|
3/4
|
PNE
|
1
|
BODY CONSTRUCTION: Thermoplastic
MAXIMUM CAPACITY: 18 GPM (PNE model)
FLOW at 10′ LIFT and 40 PSI: 10.7 GPM (PND model)
MAX LIFT: 25′
MAX SHUT-OFF PRESSURE: 78 PSI (model PND)
MAXIMUM INLET PRESSURE: 22 PSI
PRESSURE SWITCH SETTING: 30 – 50 PSI
SUCTION SIZE: 1-1/4″ NPT
DISCHARGE SIZE: 1″ NPT
AMP DRAW (full load) – 1 HP: 7.4 amps on 230v / 14.8 amps on 115v
AMP DRAW (full load) – 3/4 HP: 6.2 amps on 230v / 12.4 amps on 115v
AMP DRAW (full load) – 1/2 HP: 4.95 amps on 230v / 9.9 amps on 115v
VOLTAGE: 230V / 115V
RECOMMENDED BREAKER: see owner’s manual
LIQUID TEMPERATURE: 140 °F / (60 °C)

Pro-Source Water System Packages
Model Number | HP | Tank Size |
SNCP15H | 1/2 | 15 GAL |
SNCP42 | 1/2 | 42 GAL |
SLCP42 | 1/2 | 42 GAL |
SLDP42 | 3/4 | 42 GAL |
BODY CONSTRUCTION: Pumps: Close Grained Cast Iron / Tanks: Steel
MAXIMUM CAPACITY: model dependent (see Spec Sheet for more info)
FLOW at 10′ LIFT and 40 PSI: model dependent (see Spec Sheet for more info)
SHUT-OFF PRESSURE: 58 – 67 PSI (model and setup dependent)
MAXIMUM INLET PRESSURE: 50 PSI (total internal pump pressure not to exceed 100 PSI)
DISCHARGE SIZE: SNCP15H is 3/4″ NPT / Others are 1″ NPT
AMP DRAW (full load): model dependent
MAXIMUM WATER TEMPERATURE: 120 F (49 C)
TANK RATED “EQUIVALENCY”: SNCP15H: 6 Gal / Others: 19 Gal
TANK DRAWDOWN: SNCP15H 1.8 Gal / Others: 5.8 Gal

HMS Series pumps
ITEM # | HORSEPOWER |
---|---|
HMSD
|
3/4
|
HMSE
|
1
|
HMSF
|
1-1/2
|
BODY CONSTRUCTION: Cast Iron
MAXIMUM CAPACITY: 15.9 GPM (HMSF with Shallow Well Setup)
FLOW at 10′ LIFT and 40 PSI: 10.9 GPM (HMSE with Shallow Well Setup)
MAX LIFT: 25′ w/ Shallow Well Jet Kit / 140′ w/ Deep Well Jet Kit
MAX SHUT-OFF PRESSURE: 68 PSI (model HMSF)
MAXIMUM TOTAL PRESSURE (Inlet + Pump Pressure): HMSD: 60 PSI / HMSE: 65 PSI / HMSF: 68 PSI
PRESSURE SWITCH SETTING: 30-50 PSI
SUCTION SIZE: 1-1/4″ NPT
DRIVE SIZE: 1″ NPT
DISCHARGE SIZE: 1″ NPT
VOLTAGE: 115v / 230v 60 Hz, 1-phase
MAXIMUM LIQUID TEMPERATURE: 140 F (60 C)

HL series
ITEM # | HORSEPOWER |
---|---|
HLC
|
1/2
|
HLD
|
3/4
|
HLE
|
1
|
BODY CONSTRUCTION: Cast Iron
MAXIMUM CAPACITY: 26.8 GPM (model HLE with Shallow Well Setup)
FLOW at 10′ LIFT and 40 PSI: 13.1 GPM (model HLD with Shallow Well Setup)
MAX LIFT: 25′ w/ Shallow Well Kit / 90′ w/ Deep Well Kit
MAX SHUT-OFF PRESSURE: 127 PSI (model HLE w/ Shallow Jet)
MAXIMUM INLET PRESSURE: 50 PSI
PRESSURE SWITCH SETTINGS: 30 – 50 PSI
SUCTION SIZE: 1-1/4″ NPT
DRIVE SIZE: 1″ NPT
DISCHARGE SIZE: 1″ NPT
VOLTAGE: 230v / 115v AC 60 Hz, 1-phase
RECOMMENDED BREAKER: see owner’s manual
MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)

FN series
ITEM # | HORSEPOWER |
---|---|
FNC
|
1/2
|
FND
|
3/4
|
BODY CONSTRUCTION: Cast Iron
MAXIMUM CAPACITY: 15 GPM (FND model)
FLOW at 10′ LIFT and 40 PSI: 5.9 GPM (FNC model)
MAX LIFT: 25′
MAX SHUT-OFF PRESSURE: 70 PSI (model FND)
MAXIMUM INLET PRESSURE: FNC: 60 PSI / FND: 50 PSI
PRESSURE SWITCH SETTINGS: 30-50 PSI
SUCTION SIZE: 1-1/4″ NPT
DISCHARGE SIZE: 1″ NPT
AMP DRAW (full load): 12.2 amps (model FND on 115v)
VOLTAGE: 230v / 115v
RECOMMENDED BREAKER: see owner’s manual
MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)

FL Series Pumps
ITEM # | HORSEPOWER | MOTOR VOLTAGE | SUCTION SIZE | DRIVE SIZE | DISCHARGE SIZE | WEIGHT (LBS) |
---|---|---|---|---|---|---|
FLC
|
1/2
|
115/230
|
1-1/4″
|
1″
|
1″
|
44
|
FLD
|
3/4
|
115/230
|
1-1/4″
|
1″
|
1″
|
45
|
Quality Construction – Close-grained cast iron pump body and base are rugged one-piece unit, specially treated to resist corrosion.
Pressure Regulator – Simple, built-in regulator is performance proven. Adjustable for best performance on all deep well installations.
Provide high capacities up to 11 GPM, depths to 90 feet. They are rated for 30-50 PSI operation.
Ideal for water systems and sprinkling for homes, farms and cottages.

FH Series Pump
ITEM # | HORSEPOWER |
---|---|
FH50
|
1/2
|
Pump Case: Close-grained cast iron
Diffuser: Reinforced Polypropylene
Seal Plate: Close-grained cast iron
Impeller: Noryl®
Mechanical Shaft Seal, Type 6: Buna-N, Carbon, Ceramic, 18-8 stainless steel
Nozzle: Acetal
Venturi Tube: Acetal
1⁄4″ NPT Pipe Plug: Zinc plated steel
Mounting Base: Steel

CJ Series Pump
Catalog number | HP | Switch setting | Description | Suction size | Discharge size | motor voltage | weight |
CJ90E | 1 | 30-50 | shallow well jet | 1-1/4″ | 1″ | 115/230 | 26 |
CJ90F | 1-1/2 | 40-60 | shallow well jet | 1-1/4″ | 1″ | 115/230 | 29 |
BODY CONSTRUCTION: Stainless Steel
HORSEPOWER: Available in 1 or 1-1/2 HP
MAXIMUM CAPACITY: 18.6 GPM (CJ90F)
FLOW at 10′ LIFT and 40 PSI: 16.4 GPM (CJ90F)
MAX LIFT: 25′
MAX SHUT-OFF PRESSURE: 80 psi (CJ90F)
MAXIMUM INLET PRESSURE: 50 PSI
PRESSURE SWITCH SETTING: 30-50
SUCTION SIZE: 1-1/4″ NPT
DISCHARGE SIZE: 1″ NPT
AMP DRAW (full load): Highest: CJ90F at 19.2 amps on 115v / Lowest: CJ90E at 7.4 amps on 230v
VOLTAGE: 230v / 115v switchable
RECOMMENDED BREAKER: Voltage & Model Dependent
MAXIMUM LIQUID TEMPERATURE: 122°F (50°C)