|
-
The pumps for which Department Of Energy (DOE) is setting energy conservation standards in this rule making are consistent with the scope of applicability of the test procedure final rule.
Energy Conservation Program: Energy Conservation Standards for Pumps
Docket Number EERE–2011–BT–STD–0031
RIN 1904-AC54
Energy Conservation Program: Test Procedure for Pumps
Docket No. EERE-2013-BT-TP-0055
RIN 1905-AD50
Nomenclature, definitions, and scope has been summarized below.
Diagram
|
Nomenclature (DOE) / [Industry]
and Definition
|
Scope Refinement
|
|
End Suction Frame Mount (ESFM) [OH0, OH1]
End suction frame mounted/own bearings (ESFM) pump means a mechanically-coupled, dry rotor,
end suction pump that has a shaft input power greater than or equal to 1 hp and less than or equal to 200 hp
at BEP and full impeller diameter and that is not a pool filter pump.
Examples include, but are not limited to, pumps complying with ANSI/HI nomenclature OH0 and OH1,
as described in ANSI/HI 1.1-1.2–2014, within the specified horsepower range. |
Included:
Clean Water
1 – 200 Hp (BEP)
Flow > 25 gpm (BEP)
Head < 459 ft (BEP)
14 to 248 ºF
3600/1800 RPM
Excluded:
Non-clean water pump
Mixed/Axial Flow
Nuclear
Mil Spec
Sealless
Self-Priming
Prime Assist
Fire Pump
Sanitary (3-A Std.)
Circulator (Hydronic)
Pool Pumps
ST > 6 inch bowl |
|
End Suction Close Coupled (ESCC) [OH7]
End suction close-coupled (ESCC) pump means a close-coupled, dry rotor, end suction pump that has a
shaft input power greater than or equal to 1 hp and less than or equal to 200 hp at BEP and full
impeller diameter and that is not a pool filter pump.
Examples include, but are not limited to, pumps complying with ANSI/HI nomenclature OH7,
as described in ANSI/HI 1.1-1.2–2014, within the specified horsepower range. |
|
In-line (IL) [OH3, OH4, OH5]
In-line pump means a pump that is either a) a twin-head pump, or b) a single-stage, single-axis flow,
dry rotor, rotodynamic pump that has a shaft input power greater than
or equal to 1 hp and less than or equal to 200 hp at BEP and full impeller diameter, in which liquid is
discharged through a volute in a plane perpendicular to the shaft. Such pumps do not include pumps
that are mechanically or close-coupled, have a pump power output that is less than or equal to 5 hp at BEP
at full impeller diameter, and are distributed in commerce with a horizontal motor.
Examples include, but are not limited to, pumps complying with ANSI/HI nomenclature OH3, OH4, or OH5,
as described in ANSI/HI 1.1-1.2–2014, within the specified horsepower range. |
|
Radially Split Multi-stage Vertical in-line diffuser casing (RSV) [VS8]
Radially split, multi-stage, vertical, in-line, diffuser casing (RSV) pump means a vertically suspended,
multi-stage, single axis flow, dry rotor, rotodynamic pump that has a shaft input power greater than
or equal to 1 hp and less than or equal to 200 hp at BEP and full impeller diameter and for the
number of stages required for testing and in which:
a) liquid is discharged in a plane perpendicular to the impeller shaft;
b) each stage consists of an impeller and diffuser; and
c) no external part of such a pump is designed to be submerged in the pumped liquid.
Examples include, but are not limited to, pumps complying with ANSI/HI nomenclature VS8,
as described in the ANSI/HI 2.1-2.2–2014. |
|
Submersible Turbine (ST) [VS0]
Submersible turbine (ST) pump means a single-stage or multi-stage, dry rotor, rotodynamic pump
that is designed to be operated with the motor and stage(s) fully submerged in the pumped liquid; that
has a shaft input power greater than or equal to 1 hp and less than or equal to 200 hp at BEP and full
impeller diameter and for the number of stages required for testing; and in which:
a) each stage of this pump consists of an impeller and diffuser and
b) liquid enters and exits each stage of the bare pump in a direction parallel to the impeller shaft.
Examples include, but are not limited to, pumps complying with ANSI/HI nomenclature VS0,
as described in ANSI/HI 2.1-2.2–2014 |
|